SABER UCV >
2) Tesis >
Pregrado >

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10872/12075

Título : Pacientes obesos mórbidos con vía aérea difícil: Airtraq® vs fibroscopio flexible para intubación orotraqueal
Autor : García, Colleen C.
Vargas, Karelys V.
Palabras clave : Fibroscopio flexible
Airtraq®
obesidad mórbida
vía aérea difícil
intubación endotraqueal
Flexible Fiberscope
morbid obesity
difficult airway
endotracheal intubation
Fecha de publicación : 28-Sep-2015
Resumen : Objetivo: Comparar las características de intubación mediante Airtraq® y Fibroscopio flexible, en pacientes obesos mórbidos con vía aérea difícil anticipada que van a cirugía bariátrica. Métodos: 78 pacientes con 3 o más predictores de vía aérea difícil fueron divididos aleatoriamente en dos grupos. En el Grupo A fueron intubados a través del dispositivo Airtraq® y en el F mediante Fibroscopio flexible. Todos monitorizados con: PANI, pulsioximetría, electrocardiografía y relajación muscular. La inducción anestésica se realizó según el peso del paciente y se corroboró la intubación exitosa a través de la capnometría. Resultados: La tasa intubación exitosa fue de 100% para ambos grupos. En el Grupo F: el 20,5% de los pacientes requirió uso de técnicas alternativas para lograr la intubación, en contraparte con 5,1% en el Grupo A (p=0,043). El tiempo para lograr la intubación orotraqueal con el Fibroscopio flexible fue: 78,9 ± 60,6 seg, y con el dispositivo Airtraq®: 30,7 ± 20,9 seg (p= 0,000); ambos resultados estadísticamente significativos. Conclusiones: Nuestro estudio demuestra que la intubación orotraqueal con el dispositivo Airtraq® se logra en menor tiempo y con el uso de menos técnicas alternativas, cuando se compara con el Fibroscopio flexible en obesos mórbidos con VAD anticipada.
ABSTRACT Morbidly obese patients with difficult airway: Airtraq® vs. Flexible fiberoptic intubation Objective: To compare the characteristics of intubation with Airtraq® and Fiberscope flexible in morbidly obese patients with anticipated difficult airways going to bariatric surgery. Methods: 78 patients with 3 or more predictors of difficult airway were randomly divided into two groups. In Group A were intubated through the Airtraq® device and the F by Fiberscope flexible. All patients were monitored with: NIBP, pulse oximetry, electrocardiography and muscle relaxation. Anesthesia was performed according to patient weight and successful intubation was confirmed by capnometry. Results: The successful intubation rate was 100% for both groups. In Group F: 20.5% of patients required use of alternative techniques to achieve intubation in counterpart with 5.1% in Group A (p = 0.043). The time to achieve tracheal intubation with Flexible Fiberscope was: 78.9 ± 60.6 sec, and the Airtraq® device: 30.7 ± 20.9 sec (p = 0.000), both statistically significant results. Conclusions: Our study demonstrates that tracheal intubation with the Airtraq® device is achieved with less time and less use of alternative techniques, when compared with Flexible Fiberscope in morbidly obese patients with anticipated difficult airway.
URI : http://hdl.handle.net/10872/12075
Aparece en las colecciones: Pregrado

Ficheros en este ítem:

Fichero Descripción Tamaño Formato
Colleen Garcia, Karelys Vargas_Publicación Final.pdf3.17 MBAdobe PDFVisualizar/Abrir

Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2008 MIT and Hewlett-Packard - Comentarios